Sending CAN Messages From Komodo Duo Interface and Monitoring It With Another Komodo Interface Using Komodo GUI and Data Center
Sending CAN Messages From Komodo Duo Interface and Monitoring It With Another Komodo Interface Using Komodo GUI and Data Center

Introduction

This article focuses on how to send CAN data from one Komodo Duo interface (channel A) and monitor it in a second Komodo Duo interface (channel A). In this example, two computers are used with one Komodo interface per computer. However, the same steps can be used with both Komodo interfaces connected to a single computer.

Overview

In this article Komodo-1 channel A is connected to Komodo-2 channel A. Komodo-1 channel A sends 11 22 33 44 55 and Komodo-2 channel A monitors it.

CAN Data Transfer Guidelines

  1. Download and run the latest version of the Total Phase USB Drivers Installer.
  2. Download and unzip the latest version of Komodo GUI on PC-1. (?)
  3. Download and unzip the latest version of Data Center on PC-2. (?)
  4. Connect Komodo-1 to PC-1 via the USB connector. Connect Komodo-2 to PC-2 via the USB connector.
  5. Connect the Komodo-1 DB-9 connector channel A to Komodo-2 DB-9 connector channel A. (?)
  6. Connect 1K OHM resistor between CAN+ and CAN- in Komodo channel A block screw terminal.
  7. Launch Komodo GUI on PC-1. (?)
  8. Launch Data Center on PC-2. (?)
  9. Connect Komodo-1 port 0 to Komodo GUI. (?)
    1. Click Analyzer.
    2. Click Connect.
    3. Select the Komodo port 0.
    4. Click OK to connect to the Komodo interface.
  10. Connect Komodo-2 port 0 to Data Center. (?)
    1. Click Analyzer.
    2. Click Connect to Analyzer.
    3. Select the Komodo port 0.
    4. Click OK to connect to the Komodo interface.
  11. Configure Komodo GUI (?)
    1. Click Mode ➝ General CAN.
    2. Enable Active CAN Mode. Configure to Bitrate: 125 Khz, CAN ID: 0x123, DLC: 5, Message: 11 22 33 44 55, Ch A.
    3. Click Analyzer ➝ Run.
  12. Configure Data Center (?)
    1. Click Analyzer ➝ Device Settings ➝ CAN.
    2. Disable include packets from this device. Disable Monitor Bus B.
    3. Enable Monitor Bus A, Make Active Node, and Configure Bus A Settings.
    4. Disable Target Power. Configure to Bitrate: 125000. Disable Enable GPIO Configuration.
    5. Click Analyzer → Run Capture.
  13. On Komodo GUI click Send Message. (?)
  14. Verify that that Komodo-1 sends the data correctly, and that Komodo-2 monitors the data correctly.
  15. Figure 1: Komodo CAN Transfer - Komodo GUI



    Figure 2: Komodo CAN Transfer - Data Center



    Notes

    For additional information, take a look at the Komodo interface user manual, Komodo GUI user manual and Data Center user manual